Elevator Monarch Inverter ME320L

Elevator Monarch Inverter ME320L 100% Replace Yaskawa L1000A
220-1P-50/60Hz, 220-3P-50/60Hz, 380-3P-50/60Hz, for Elevator
Sale: 28
$313.50 - $330.00
/ pc
|
10 pc(Min. Order)
20-49 pc 2.00% Off
50-99 pc 3.00% Off
>=100 pc 5.00% Off
Final Solution:
$0.00
(100 In Stock)
$0.00
Selected List
0
No Selected Products
Payment:
Bank Transfer
Western Union
Description Delivery / Packing
Description


Elevator Monarch Inverter ME320L Drive generate power of movement for Elevator

Customers check its function and parameters in accordance with its specification and type to ensure its performance matching with the elevator actual state.

Elevator Monarch Inverter ME320L 5.5~22kw Elevator
220-1P-50/60Hz, 220-3P-50/60Hz, 380-3P-50/60Hz


Specification

Electrical data input voltage 220-1P-50/60Hz, 220-3P-50/60Hz,  380-3P-50/60Hz
fluctuation not exceed +-10%, unbalanced rate <3%
input frrequency 50/60Hz -+5%
output voltage 0~input voltage
output frequency 0~100.0Hz
Input / Output control mode  V/f control, SVC control, VC control
overload capbility 2 minuites for 150% output current :
10 seconds for 180% output current 
velocity resolution digital setting. 0.01Hz:
analogue setting:0.1xMax,
freguency
SVC control speed control accuracy:-+0.5%:
speed control range :1:1000:
Torque control response;<200ms:
Starting Torque: 180% rated torque / 0.5Hz
VC control speed control accuracy:-+0.05%:
speed control range :1:1000:
Torque control response;<50ms:
Starting Torque: 200% rated torque / 0Hz
Elevator Basic analog power supply `+10V. Load capacity 100mA
`-10V. Load capacity   05mA
digital power supply `+24V. Load capacity 200mA
analog input AI1: Voltage 0~10V; AI2~AI4
 (selectable voltage/current)`-10V-+10V/0~20mA
AI4 support different input
analog output AO1~AO2:
(selectable voltage/current)`-10V-+10V/0~20mA
digital input DI~DI6(control board)
DI7~DI12 (I/O board)
Input voltage :0~30VDC
digital output D01~D02: Max.output current :50mA
relay output R1A/R1B/R1C R2A/R2B/R2C
 R3A/R3B/R3C R4A/R4B/R4C
contactor capacity : 250VAC/3A or 30VDC/1A
Delivery / Packing
NOTE:
         Client can choose below transporation way to deliver your cargos according to your order, the cost of shippingwill be charged from each order .

 
Deilver Optional  Deliver Time  Deliver Service  Client Provide
DHL / FedEx 3-5  Workding Days Door to Door Company Name :
Address :
Post Code:
Tel Number:
Consginee :
UPS /  TNT 5-10 Workding Days Door to Door Company Name :
Address :
Post Code:
Tel Number:
Consginee :
EMS 10-15 Workding Days Door to Door Company Name :
Address :
Post Code:
Tel Number:
Consginee :
AIR 5-8  Workding Days Factory to Airport Client Airport Name
SEA 25-45  Workding Days Factory to Airport Client Seaport Name


  
icon